Scholarly record
SIMULATION OF GROUND THERMO-PHYSICAL CAPACITY FOR A VERTICAL CLOSED-LOOP GROUND-COUPLED HEAT PUMP SYSTEM
Abstract
The ground serves as an ideal heat source for monovalent ground-coupled heat pump (GCHP) systems. This paper presents a working methodology and develops an analytical model for evaluation of the ground thermal conductivity and the borehole thermal resistance using a thermal response test (TRT). Additionally, this paper uses the Earth Energy Designer (EED) simulation program developed on the basis of the line-source model to calculate the fluid temperature for a case study of the ground heat exchanger according to the monthly heating and cooling loads and the borehole thermal resistance. Through the ground TRT, the length of the loops is properly determined, the operating performance of the system is provided, and supplementary costs (e.g. extra loops, boreholes, glycol, etc.) are avoided. The average fluid temperature in the ground for cooling, heating and domestic hot water production thermal power over a period of 25 years was simulated. Analysing the time evolution of the fluid temperatures in the ground for the peak loads reveals that these values are approximately constant, meaning that the heat source (ground) is fully regenerated and thus the GCHP will maintain high performance in operation.
Publication Impact Profile
Publication details
References13
Pahud D., Mattthey B., Comparison of the thermal performance of double U-pipe borehole heat exchanger measured in situ, Energy and Buildings, vol. 33, no. 5, pp. 503-507, 2001.
Bose J.E., Smith M.D., Spitler J.D., Advances in ground source heat pump systems – An international overview. In: Proceedings of the 7th International Conference on Energy Agency Heat Pump, Beijing, China, 2002, pp. 313-324.
Luo J., Rohn J., Bayer M., Priess A., Modeling and experiments on energy loss in horizontal connecting pipe of vertical ground source heat pump system, Applied Thermal Engineering, vol. 60, pp. 55-64, 2013.
Sarbu I., Sebarchievici C., General review of ground-source heat pump system for heating and cooling of buildings, Energy and Buildings, vol. 70, no. 2, pp. 441-454, 2014.
Philappacopoulus A.J., Berndt M.L., Influence of rebounding in ground heat exchangers used with geothermal heat pumps, Geothermic, vol. 30, no. 5, pp. 527-545, 2001.
Rawlings R.H.D., Sykulski J.R., Ground source heat pumps: a technology review, Building Services Engineering Research and Technology, vol. 20, no. 3, pp. 119-129, 1999.
Floridesa G., Kalogirou S., Ground heat exchanger – A review of systems, models and applications, Renewable Energy, vol. 32, no. 15, pp. 2461-2478, 2007.
Sarbu I., Sebarchievici C., Ground-source heat pumps: Fundamentals, experiments and applications, Elsevier, Oxford, 2015.
Eskilson P., Thermal analysis of heat extraction boreholes, Doctoral thesis, University of Lund, Sweden, 1987.
Austin W.A., Yavuzturk C., Spitler J.D., Development of an in-situ system for measuring ground thermal properties, ASHRAE Transactions, vol. 106, no. 1, pp. 365-379, 2000.
Gehlin S., Thermal response test, in-situ measurements of thermal properties in hard rock, Licentiate thesis, Lulea University of Technology, Sweden, vol. 39, pp. 5-10, 1998.
Hellström G., Ground heat storage: thermal analyses of duct storage systems, Doctoral thesis, Department of Mathematical Physics, University of Lund, Sweden, 1991.
Ingersoll L.R., Plass H.J., Theory of the ground pipe source for the heat pump, ASHVE Transactions, vol. 54, pp. 339-348, 1948.
Citing literature
Number of times cited according to Crossref: 3
View or Download full articleAccess options
SWS access login
Login as SWS Scientific CommitteeLogin as SWS Scientific PartnerLogin as SWS AuthorAuthors and approved SWS contributors will read and export their own linked papers after identity matching by SWS profile, email and SGEM GlobalID.
For librarian assistance: [email protected]
Purchase Instant Access
- Article can be downloaded after successful payment.
- Article may be used according to SWS library access terms.
- Article cannot be redistributed.