Publication
RESPONSE OF MASONRY PARTITION WALL TO DYNAMIC LOADING INDUCED BY EXPLOSION
(STEF92 Technology, 2017-06-20, Miroslav Mynarz, Lucie Mynarzova)
Show more
This contribution results from the experiments conducted in the experimental gallery in the limestone pit. The gallery consists of three horizontal parts, two of them are parallel. The premises of the experimental galleries are used for testing and research in the area of explosion prevention. The partition masonry walls were built inside the gallery and they were subjected to the blast load induced by air-gas mixture. The paper introduces the principles for determining the dynamic load and for its simplification,...
Green Buildings Technologies and Materials2017