|
ELECTROCHEMICAL DETERMINATION OF LEAD IN WATER SAMPLES USING MODIFIED ELECTRODE BASED ON POLYAZULENE DERIVATES
|
|
|
M. E. Ungureanu;G. G. Vasile;G. L. Arnold;L. Birzan;G. O. Buica
|
|
|
||
|
|
|
|
1314-2704
|
|
|
||
|
English
|
|
|
17
|
|
|
51
|
|
|
|
|
|
||
|
The purpose of the study was to develop an electrochemical method for detection of lead at low level of contamination in water samples using a carbon glassy electrode modified with the functionalized azulene: (2E)-2-(azulen-1-ylmethylidene) hydrazine carbothioamide (L) as a complexing polymer film. The modified electrodes were prepared in L solutions (1mM) in acetonitrile (CH3CN) containing tetra n-butyl ammonium perchlorate (0.1 M TBAP) as supporting electrolyte. The analyses were performed on Autolab PGSTAT 12 Potentiostat, all the reagents used were ultratrace quality. The electrochemical method include four steps: 1) polymeric film formation by controlled potential electrolysis (CPE) at 1.7V using a charge of 1 mC under argon atmosphere; 2) film conditioning in 0.1 M buffer acetate solution using cyclic voltametry; 3) complexation in a standard solution prepared from lead nitrate (II) using ultrapure water as matrix or a real sample; 4) stripping differential pulse voltammetry method (DPV) in acetate buffer at 5.5 pH, after 180 seconds reduction time at a reduction potential of -1.2 V. The determination time for a standard solution or real sample is arround 45 minutes. The calibration curve was ploted in the range 1 to 50 ?g/L Pb (II). The precision experiments were performed at 10 ?g/L Pb (II). The precision for polymeric film formation on the glassy carbon electrode was 13.5%, while the intermediate precision test indicated a value of 15.5%. Evaluation of the method performant parameters confirm that the proposed method is suitable to detect and quantify lead content in water samples.
|
|
|
conference
|
|
|
||
|
||
|
17th International Multidisciplinary Scientific GeoConference SGEM 2017
|
|
|
17th International Multidisciplinary Scientific GeoConference SGEM 2017, 29 June - 5 July, 2017
|
|
|
Proceedings Paper
|
|
|
STEF92 Technology
|
|
|
International Multidisciplinary Scientific GeoConference-SGEM
|
|
|
Bulgarian Acad Sci; Acad Sci Czech Republ; Latvian Acad Sci; Polish Acad Sci; Russian Acad Sci; Serbian Acad Sci & Arts; Slovak Acad Sci; Natl Acad Sci Ukraine; Natl Acad Sci Armenia; Sci Council Japan; World Acad Sci; European Acad Sci, Arts & Letters; Ac
|
|
|
359-364
|
|
|
29 June - 5 July, 2017
|
|
|
website
|
|
|
cdrom
|
|
|
3930
|
|
|
lead; water; stripping voltammetry; polymeric film; poly[(2E)-2-(azulen-1-ylmethylidene) hydrazine carbothioamide]
|
|