Scholarly record
ADVANCED AND PRECISELY PROCESS OF CLORINE DISINFECTION FOR DRINKING WATER
Abstract
This paper deals with disinfection of drinking water at пїЅAquatim S.AпїЅ. The disinfection plant is part of an investment plan to provide conformation with the Romanian Law 485/2002 concerning drinking water quality and European Union Water Frame Directive. The new facility employs modern techniques of storage, dosage, injection and neutralization of chlorine. Under these circumstances, the risk of chlorine leakage decreased and increased the accuracy of chlorine dosage. The regulation and control of the process is carried out by 4 automation-monitoring close-loops according to the deviation, the output signals are free residual chlorine after 30 minutes contact time and water flow rate. The accomplishment of the new chlorination plant provides consumers protection by supplying good quality water, operation under totally secure conditions and environmental protection. The chlorination plant is highly flexible and disinfection can be carried out according to water quality in order to maintain the formation of chlorinated organic compounds at a minimum. An extra safety for consumers is provided by the final close-loop that maintains the free chlorine concentration in the supplied drinking water constant as against the set reference and, on the other hand, offers the possibility of a quick change of the free chlorine concentration. After the start up of the plant, chlorine consumption decreased by about 33%
Publication Impact Profile
Publication details
References11
Tuthill RW, Giusti RA, Moore GS, Calabrese EJ. Health effects among newborns after prenatal exposure to ClO2-disinfected drinking water. Environ Health Perspect 1982;46:39–45.
Savitz DA, Andrews KW, Pastore LM. Drinking water and pregnancyoutcome in central North Carolina: source, amount, and trithalomethanelevels. Environ Health Perspect 1995;103:592–6.
Bove FJ, Fulcomer MC, Klotz JB, Esmart J, Dufficy EM, Savrin JE. Public drinking water contamination and birth outcome. Am J Epidemiol 1995;141:850–62.
APHA, AWWA and WEF (1995) Standard Methods forthe Examination of Water and Waste Water.Washington, DC
Romanian normative regarding the design, construction and operation of the water supply and sewerage systems of the localities. Indicative NP 133-2011.
Jolley C,Johnson K., Minear M., Jacobs A.,Water Chlorination: Chemistry, Environmental Impact and Health, Volumul 6, 1987
Robert Radvanovsky, Jacob Brodsky, SCADA/Control Systems Security, 2013
Stuart A. Boyer Scada: Supervisory Control And Data Acquisition, 2009
Florescu C., Mirel I., Carabeț A., Stăniloiu C, Water supply (Alimentări cu apă), www.ct.upt.ro/users/ConstantinFlorescu/index.htm, 2015
Giurconiu M., Mirel I., Carabeț A., Chivereanu D., C Florescu, Stăniloiu C., Hydro-hydraulic constructions and installations (Construcții și instalații hidroedilitare), Editura de Vest, Timisoara, 2002
Aquatim - Regional operating company for the water and sewerage system in the Timiș County
View or Download full articleAccess options
SWS access login
Login as SWS Scientific CommitteeLogin as SWS Scientific PartnerLogin as SWS AuthorAuthors and approved SWS contributors will read and export their own linked papers after identity matching by SWS profile, email and SGEM GlobalID.
For librarian assistance: [email protected]
Purchase Instant Access
- Article can be downloaded after successful payment.
- Article may be used according to SWS library access terms.
- Article cannot be redistributed.