SWS Academic Research eLibraryEarth & Planetary Sciences

Scholarly record

EVALUATION OF THE QUALITY OF THE INDOOR ENVIRONMENT IN COLLEGE CLASSROOMS

B Chudikova

First published: 2018-06-20https://doi.org/10.5593/sgem2018/6.3/s26.023View metrics

Abstract

The topic of increased CO2 concentration is very actual in the Czech Republic, especially in the connection to the current effort for a massive revitalization of buildings, which aims to reduce the energy performance of buildings. Both residential and civil buildings revitalization includes predominantly replacement of windows and insulation by the contact system. Exchange of windows and high-quality contact insulation then result in almost no infiltration at all. So, when the forced ventilation is not compulsory proposed to such revitalised buildings, due to insulated thermal bonds and tight windows, the problem with an increased CO2 concentration in the indoor environment appears. Increased concentration of CO2 means, in less serious eventualities, a concentration disorder. In more serious cases, it may cause headaches, nausea, difficulties in breathing or even loss of consciousness. It is evident that it presents a serious problem that cannot be easily revealed by laymen as he could misinterpret his sleepiness or nausea as a sigh of his poor state of health. The current legislation deals with the problem of increased CO2 concentration in schools, but only taking kindergartens, elementary and secondary schools into consideration. As far as universities are concerned, they are mentioned only marginally in Regulation No. 268/2009 Coll., dealing with technical requirements of buildings, which indicates the CO2 concentration - 1500 ppm as limit. College students spend even longer period of time in classrooms than elementary or secondary school students, and mostly without the possibility of supplying fresh air. That can be strongly reflected in their concentration. The purpose of the article is to measure and evaluate indoor air quality in the classrooms of V?B-TUO Faculty of Civil Engineering. The analysis of carbon dioxide, temperature and humidity of indoor air was conducted during the lectures. Measurements took place in three different classrooms with different number of people, with different internal gains and with different ventilation modes.

Publication Impact Profile

PlumX
  • Captures
  • Mendeley - Readers: 5

Publication details

Title
EVALUATION OF THE QUALITY OF THE INDOOR ENVIRONMENT IN COLLEGE CLASSROOMS
Authors
B Chudikova
Proceedings
SGEM International Multidisciplinary Scientific GeoConference EXPO Proceedings; 18th International Multidisciplinary Scientific GeoConference SGEM2018, Nano, Bio and Green - Technologies for a Sustainable Future
Publisher
STEF92 Technology
Year
2018
Pages
173-180
SWS Citekey
Chudikova201826173180
ISSN
1314-2704
ISBN
978-619-7408-52-2
Language
en
Publication type
Conference Paper
Keywords
References0
0references registered for this publication

Structured references will appear here after the reference import pass. The count is preserved now so the scholarly record is not incomplete.

View or Download full articleAccess options
Full paper accessChoose SWS login, librarian support, or instant article download.

SWS access login

Login as SWS Scientific Committee

Authors and approved SWS contributors will read and export their own linked papers after identity matching by SWS profile, email and SGEM GlobalID.

For librarian assistance: [email protected]

Purchase Instant Access

48-hour online accessComing soon
Online-only accessComing soon
Download the full article in PDF formatEUR 35
  • Article can be downloaded after successful payment.
  • Article may be used according to SWS library access terms.
  • Article cannot be redistributed.
Get full paper