EVALUATION OF THE QUALITY OF THE INDOOR ENVIRONMENT IN COLLEGE CLASSROOMS
Abstract
The topic of increased CO2 concentration is very actual in the Czech Republic, especially in the connection to the current effort for a massive revitalization of buildings, which aims to reduce the energy performance of buildings. Both residential and civil buildings revitalization includes predominantly replacement of windows and insulation by the contact system. Exchange of windows and high-quality contact insulation then result in almost no infiltration at all. So, when the forced ventilation is not compulsory proposed to such revitalised buildings, due to insulated thermal bonds and tight windows, the problem with an increased CO2 concentration in the indoor environment appears. Increased concentration of CO2 means, in less serious eventualities, a concentration disorder. In more serious cases, it may cause headaches, nausea, difficulties in breathing or even loss of consciousness. It is evident that it presents a serious problem that cannot be easily revealed by laymen as he could misinterpret his sleepiness or nausea as a sigh of his poor state of health. The current legislation deals with the problem of increased CO2 concentration in schools, but only taking kindergartens, elementary and secondary schools into consideration. As far as universities are concerned, they are mentioned only marginally in Regulation No. 268/2009 Coll., dealing with technical requirements of buildings, which indicates the CO2 concentration - 1500 ppm as limit. College students spend even longer period of time in classrooms than elementary or secondary school students, and mostly without the possibility of supplying fresh air. That can be strongly reflected in their concentration. The purpose of the article is to measure and evaluate indoor air quality in the classrooms of V?B-TUO Faculty of Civil Engineering. The analysis of carbon dioxide, temperature and humidity of indoor air was conducted during the lectures. Measurements took place in three different classrooms with different number of people, with different internal gains and with different ventilation modes.
Publication Impact Profile
Publication details
References5
Decree No. 410/2005 Coll., On sanitary requirements for premises and operation of facilities and facilities for education and training of children and adolescents, as amended
ČSN 73 0540-2 Thermal protection of buildings - Part 2: Requirements. ÚNMZ. 2011.
Decree No. 268/2009 Coll., Amending the Decree on Technical Requirements for Buildings as amended
ZMRHAL, V. Pollutants from the internal environment. In: Ventilation of Schools - Proceedings of Lectures. 2013.
GALDA, Zdenek, Veronika SIPKOVA, Jiri LABUDEK a Pavel GERGELA. Experimantal measurements of the CO2 in the summer months in the passive house. In: International Multidisciplinary Scientific GeoConference Surveying Geology and Mining Ecology Management, SGEM 2015. Volume 2. Sofia: STEF92 Technology, 2015, s. 127-132. DOI: 10.5593/SGEM2015/B62/S26.017. ISBN 978-619-7105-43-8. ISSN 1314-2704.
View or Download full articleAccess options
SWS access login
Login as SWS Scientific CommitteeLogin as SWS Scientific PartnerLogin as SWS AuthorAuthors and approved SWS contributors will read and export their own linked papers after identity matching by SWS profile, email and SGEM GlobalID.
For librarian assistance: [email protected]
Purchase Instant Access
- Article can be downloaded after successful payment.
- Article may be used according to SWS library access terms.
- Article cannot be redistributed.