Scholarly record
EVALUATING MEASUREMENT UNCERTAINTY TO CALIBRATING THE SECONDARY STANDARD VOLUME MEASURES, WITH A RULER ON THE NECK
Abstract
The paper refers to the evaluation and calculation of the uncertainty of measurement in the calibration of secondary standard volume measures, with a ruler on the neck, which equips standard installation for liquids flow meter verification. Calibration involves assigning actual values to certain nominal values, materialized on a standard scale. For the design and construction of a secondary volume measure, it is necessary to take into account all metrological requirements related to the shape and materials from which they are built to ensure correct filling and complete emptying of the standard, the possibility of measuring the leakage time, as well as sufficient mechanical strength to prevent deformations that would change the volume during the measurement. Calibration is performed by the volumetric method using a metallic primary standard measure of the overflow volume, pipette, thermometer, chronometer. Evaluation of the measurement uncertainty of the calibration standard measures secondary volume with the scale to the neck, involves knowing the sources of uncertainty and the measurement uncertainty components when determining the volume with primary volume measurement and the temperature correction factor.
Publication Impact Profile
Publication details
References9
OIML R 120. Edition 2010 (E), Standard capacity measures for testing measuring systems for liquids other than water.
ISO 8316:1987, Measurement of Liquid Flow In Closed Conduits – Method By Collection of The Liquid In A Volumetric Tank.
EA-4/02, Expression of the Uncertainty of Measurement in Calibration.
ISO 5168, Fluids flow measurement – Accuracy calculus.
Costea O, Donciu C, Labview based analog and digital instrument's automated calibration, Management of Technological Changes, vol. 1, pp. 473-476, 2009.
Toma D, Issues related to the adapting of variable operating regime pumping plants by the use of variable speed drives, “Ovidius” University Annals - Constantza, Year XIV, Issue 14, Series: Civil Engineering, ISSN 1584-5990, pp. 111-119, 2012.
Luca Mihail, Toma Daniel, Bălan Anca, Luca Alexandru Lucian, Apetroi Ioan, The adduction pipes management on limiting water loss, Revista Romaqua, Volume 106, Issue 8, pag. 19-30, 2015
Popescu Șt, Marcoie N, Toma D, Modelling of a hydrophore pumping facility in slow variable operational regimes, Buletinul Institutului Politehnic din Iași, Tomul LIV (LVIII), Fasc. 2, pag. 57- 66, 2008.
Bartha I., Marcoie N., Molnar A.G., Luca L.A., Toacă D., Toma D., Filtration geometric models, “Ovidius” University Annals - Constantza, Year XIV, Issue 14, series: Civil Engineering, ISSN 1584-5990, pp. 131-138, 2012
View or Download full articleAccess options
SWS access login
Login as SWS Scientific CommitteeLogin as SWS Scientific PartnerLogin as SWS AuthorAuthors and approved SWS contributors will read and export their own linked papers after identity matching by SWS profile, email and SGEM GlobalID.
For librarian assistance: [email protected]
Purchase Instant Access
- Article can be downloaded after successful payment.
- Article may be used according to SWS library access terms.
- Article cannot be redistributed.


