IMPACT OF INITIATOR PLACEMENT ON IGNITION OF THE VERTICALLY POSITIONED ELECTRICAL CABLE
Abstract
The cone heater is one of the primary sources of radiant heat in the field of fire protection. It is increasingly used not only for measurements related to building materials but also for other flammable objects, that may be exposed to heat radiation during their lifetime or during a fire. Such measurements are more specific in the case of electric cables. They can be exposed to heat individually or in bundles. Their positioning may be in the horizontal or vertical direction, with the latter prevails in real-life conditions. The submitted paper deals with the initiation characteristics of a separate, vertically oriented electric cable. The three initiator source positions were compared: above the sample, at the upper edge of the sample and at the center of the sample. In all positions, 11 samples were tested, one at each heat flow. The heat flow density ranged from 35 kW.m-2 to 85 kW.m-2 with a 5 kW.m-2 increment. The critical heat flux value was calculated from the obtained data of the time to sample ignition. The results show that for the given test method the initiator position has no significant impact, but as the most easily ignitable option appears to be the variant with a spark initiation at the top edge of the sample.
Publication Impact Profile
Publication details
References11
Cadick J., Cable Materials and Construction, Cables and wiring, USA,1999, pp 15-35.
Moore G. F., Basic Electrical Theory Applicable to Cable Design, Electric Cables Handbook, UK, 2000, pp 9-32.
National Research Council, Task Force on Flammability, Smoke, Toxicity, and Corrosive Gases of Electric Cable Materials, USA, 1978, 155 p.
Chen C., Chen J., Zhao X., Shi C., Experimental investigation on combustion characteristics of steel cable for cable-stayed bridge. Journal of Thermal Analysis and Calorimetry, First online, 2018, pp 1-11.
Hirschler M.M., Comparison of large-and small-scale heat release tests with electrical cables, Fire and Materials, 1994, 18.2: 61-76.
Vuki a.s., Cables/káble, 1. Silové káble/1.1 Silové bezhalogénové káble/CHKE-V B2ca(s1d1) PS30,60,90
Hirschler M.M., Electrical cable fire hazard assessment with the cone calorimeter, In: Fire hazard and fire risk assessment, ASTM International, 1992.
Barnes M. A., Briggs P. J., Hirschler M. M., Matheson A. F., O'Neill T. J., A Comparative Study of the Fire Performance of Halogenated and Non-Halogenated Materials for Cable Applications, Part II Tests on Cable, Fire and materials, 1996, 20.1: 17-37.
Quintiere J. G., A theoretical basis for flammability properties. Fire and Materials: An International Journal, 2006, 30.3: 175-214.
Brown J. E., Braun E., Twilley W. H., Cone calorimeter evaluation of the flammability of composite materials, US Department of Commerce, National Bureau of Standards, 1988, 61 p.
Fateh T., Rogaume T., Luche J., Richard F.,Jabouille F., Characterization of the thermal decomposition of two kinds of plywood with a cone calorimeter–FTIR apparatus, Journal of Analytical and Applied Pyrolysis, 2014, 107: 87-100.
View or Download full articleAccess options
SWS access login
Login as SWS Scientific CommitteeLogin as SWS Scientific PartnerLogin as SWS AuthorAuthors and approved SWS contributors will read and export their own linked papers after identity matching by SWS profile, email and SGEM GlobalID.
For librarian assistance: [email protected]
Purchase Instant Access
- Article can be downloaded after successful payment.
- Article may be used according to SWS library access terms.
- Article cannot be redistributed.