SWS Academic Research eLibraryEarth & Planetary Sciences

Scholarly record

MEASUREMENT TIME ESTIMATION OF CO2, CH4, N2O AND NH3 IN CLOSED CHAMBERS AND RECIRCULATION SYSTEM WITH PICARRO G2508 ANALYSER

Kristine Valujeva, Jovita Pilecka, Olga Frolova, Laima Berzina, Inga Grinfelde

First published: 2017-06-20https://doi.org/10.5593/sgem2017/41/s19.066View metrics

Abstract

The European Union has set a target to cut its greenhouse gas emission levels by 80% to 95% until 2050, if compared to 1990. Agricultural soil is an important carbon store and food provider in the world as well as greenhouse gas emission reducer via carbon sequestration. In order to assess the climate change mitigation effectiveness of the measures, it is necessary to obtain statistically significant data before and after the implementation. The greenhouse gas measurements from soil are commonly determined using static chamber-based method in which the gas sample is collected at regular intervals and stored for later analysis by gas chromatography. Picarro G2508 performs measurements in field or laboratory directly from the chamber with the interval of one second. The aim of the study was to determine the optimal measurement time for greenhouse gas measurements in different soil types by using mobile ring-down spectrophotometer Picarro G2508. N2O, CH4, CO2, NH3 and measurement data from four chambers and laboratory experiments were used. Field measurements were carried out using static chambers with the diameter of 23 cm and volume of 3 litres, which was connected to the Picarro G2508 via tube with an outer diameter of 0.125 inches. Recirculation system with the chamber volume of 2 litres was used to make the laboratory experiment. The linear regression was used to evaluate the measurement time and to compare the stability of emission coefficients. The results showed that statistically significant optimum measurement time is 8-10 minutes on a field and 2-4 minutes in laboratory.

Publication Impact Profile

PlumX
  • Citations
  • CrossRef - Citation Indexes: 4
  • Scopus - Citation Indexes: 12
  • Captures
  • Mendeley - Readers: 13

Publication details

Title
MEASUREMENT TIME ESTIMATION OF CO2, CH4, N2O AND NH3 IN CLOSED CHAMBERS AND RECIRCULATION SYSTEM WITH PICARRO G2508 ANALYSER
Authors
Kristine Valujeva, Jovita Pilecka, Olga Frolova, Laima Berzina, Inga Grinfelde
Proceedings
SGEM International Multidisciplinary Scientific GeoConference EXPO Proceedings; 17th International Multidisciplinary Scientific GeoConference SGEM2017, Energy and Clean Technologies
Publisher
STEF92 Technology
Year
2017
Pages
519-526
SWS Citekey
Valujeva201719519526
ISSN
1314-2704
ISBN
978-619-7408-06-5
Language
en
Publication type
Conference Paper
Keywords
References0
0references registered for this publication

Structured references will appear here after the reference import pass. The count is preserved now so the scholarly record is not incomplete.

Citing literature

Number of times cited according to Crossref: 4

View or Download full articleAccess options
Full paper accessChoose SWS login, librarian support, or instant article download.

SWS access login

Login as SWS Scientific Committee

Authors and approved SWS contributors will read and export their own linked papers after identity matching by SWS profile, email and SGEM GlobalID.

For librarian assistance: [email protected]

Purchase Instant Access

48-hour online accessComing soon
Online-only accessComing soon
Download the full article in PDF formatEUR 35
  • Article can be downloaded after successful payment.
  • Article may be used according to SWS library access terms.
  • Article cannot be redistributed.
Get full paper