Scholarly record
ASSESSMENT OF THE ENVIRONMENTAL IMPACT OF REFRIGERATED CONTAINERS TRANSPORTED BY SEA
Abstract
This article attempts to assess the impact of refrigerant plants used to cool the containers transported by sea on the environment. The process is based on studies carried out on one of the merchant ship capable of transporting both refrigeration and classic containers. The data necessary to perform the analysis come from reports on units damaged over two years. Subjects? CO2 (carbon dioxide) emissions resulting from the consumption of energy used by the refrigeration equipment and its equivalent associated with the immediate impact of refrigerants leakage to the atmosphere were chosen as environmental impact indicators. Ultimate environmental impact assessment uses the TEWI factor. An attempt to determine this index for the entire period of studies as well as for individual voyages was made. However, for a single voyage, refrigeration containers on the surveyed units accounted for an average of 12% of the whole load. Introduction presents the characteristic of refrigerated containers and the problems which occur during their explanation. Next, the research meteorology is presented. Eventually, the research results are presented and discussed. The summary and conclusions close the work.
Publication Impact Profile
Publication details
References7
S. Winfried i R. Jan-Martin, „The analysis of the emissions of fluorinated greenhouse gases from refrigeration and air conditioning equipment used in the transport sector other than road transport and options for reducing these emissions Maritime, Rail, and Aircraft Sector,” Prepared for the European Commission (DG Environment), 2007.
Drewry Publishing, „Drewry Reefer Shipping market review and forecast 2013/14,” London, 2014.
S. A. Tassou i I. N. Grace, „Fault diagnosis and refrigerant leak detection in vapour compression refrigeration systems,” International Journal of Refrigeration, nr 28, pp. 680-688, 2005.
Carrier, Container Refrigeration. OPERATION AND SERVICE for 69NT20-- 551--300 TO 399 Container Refrigeration Units, 2004.
PN-EN 378-1:2017-03. Instalacje ziębnicze i pompy ciepła - Wymagania dotyczące bezpieczeństwa i ochrony środowiska, 2017.
W. B. Fitzgerald, O. J. Howitt, I. J. Smith and A. Hume, "Energy use of integral refrigerated containers in maritime transportion," Energy Policy, no. 39, pp. 1885-1896, 2011.
T. Chu-Van, Z. Ristovski, A. M. Pourkhesalian, T. Rainey, V. Garaniya, R. Abbassi, S. Jahangiri, H. Enshaei, U.-S. Kam, R. Kimball, L. Yang, A. Zare, H. Bartlett
Citing literature
Number of times cited according to Crossref: 1
View or Download full articleAccess options
SWS access login
Login as SWS Scientific CommitteeLogin as SWS Scientific PartnerLogin as SWS AuthorAuthors and approved SWS contributors will read and export their own linked papers after identity matching by SWS profile, email and SGEM GlobalID.
For librarian assistance: [email protected]
Purchase Instant Access
- Article can be downloaded after successful payment.
- Article may be used according to SWS library access terms.
- Article cannot be redistributed.


